Download Printable PDF Of This Page
UL LISTED CLASS 2
POWER SUPPLY,
60 THROUGH 360 WATT MODELS,
12 AND 24 VOLT AC OUTPUT

- Core And Coil - Split Bobbin
Isolation, VDE Design
- Fusing - Circuit
Protector,
Manual Reset Overload Protection
- Multiple Class 2 Circuits
- Magnetic Dimmer Ready, Input Dimmable
- Made in USA
- UL Listed
- CSA Approved
A Class two transformer may be connected to any resistive load at or below its maximum output rating. National Electrical Code requires any
Class 2 circuit be limited to 60VA @ 12 volts or 100VA @ 24 volts, to a maximum of 360VA for multiple circuit units.
Examples of common uses include incandescent lamps,
LED lamps, solenoid coil and bell ringing circuits.
Made in U.S.A.

| FEATURES -
ALL UNITS DIMMABLE |
|
| AC Single Circuit Class 2 Transformers |
AC Multiple Circuit Class 2 Power Units |
- Manual Reset Overload Protection
- Mounting Brackets
- 1/2" input and output nipples located for direct “J” box
entry
- UL Listed Class 2 Transformers File E120561 (meets or exceeds the
requirements set forth in Underwriters Laboratories
Standard for safety UL5085)
- Available with Indoor/Outdoor Enclosure Type 3R. (PDF Link)
|
- Manual Reset Overload Protection, one per Class 2 circuit
- Indoor/Outdoor enclosure, rainproof with wall mount brackets.
- Wiring Compartment with optional 6' input cord Output
terminals accessed by 1/2" / 3/4" electrical knockouts.
- UL Listed Class 2 Power Unit/Sign Component File E325754 (meets or exceeds the requirements set forth in Underwriters Laboratories Standard for safety UL1012/UL1310.)
|
| SPECIFICATIONS AND ORDERING
INFORMATION - SINGLE CIRCUIT - DIMMABLE |
Input |
Output |
Max Rated Load |
| 120V,
60HZ
208 - 240V, 60HZ
277 - 480V, 60HZ |
12V
or
24V |
12V
- 60VA
24V - 60,100VA |
|
|
Ordering Example: (Model 601-24B)
60 |
1 |
- |
24 |
B |
VA |
INPUT |
OUTPUT |
|
60
= 50-60VA
10 = 100VA |
1
= 120 Volt Input
2 = 208/240 Volt Input
4 = 277/480 Volt Input |
Output
Voltage
12V or 24V |
A
= Separate Input and Output
nipples
B = One Input and Output
Nipple (End) |
Compatible with forward phase dimmers designed specifically for magnetic or inductive circuits. See PDF for detailed application information. |
| SPECIFICATIONS AND ORDERING
INFORMATION - MULTIPLE CIRCUIT - DIMMABLE |
| MODEL NUMBER |
INPUT |
OUTPUT |
| VAC |
Hz |
AMPS (Max.) |
VAC |
AMPS (Max.) |
Watts |
| C2240-12 |
120 |
50/60 |
2.2 |
12 |
5A Per Circuit 4 x 60VA Class 2 Circuits |
240 |
| C2240-12-240 |
240 |
50/60 |
1.1 |
12 |
5A Per Circuit 4 x 60VA Class 2 Circuits |
240 |
| C2240-12-277 |
277 |
50/60 |
0.95 |
12 |
5A Per Circuit 4 x 60VA Class 2 Circuits |
240 |
|
| C2288-24 |
120 |
50/60 |
2.6 |
24 |
4A Per Circuit 3 x 96VA Class 2 Circuits |
288 |
| C2288-24-240 |
240 |
50/60 |
1.3 |
24 |
4A Per Circuit 3 x 96VA Class 2 Circuits |
288 |
| C2288-24-277 |
277 |
50/60 |
1.1 |
24 |
4A Per Circuit 3 x 96VA Class 2 Circuits |
288 |
|
| C2350-12 |
120 |
50/60 |
3.2 |
12 |
5A Per Circuit 6 x 60VA Class 2 Circuits |
360 |
| C2350-12-240 |
240 |
50/60 |
1.6 |
12 |
5A Per Circuit 6 x 60VA Class 2 Circuits |
360 |
| C2350-12-277 |
277 |
50/60 |
1.34 |
12 |
5A Per Circuit 6 x 60VA Class 2 Circuits |
360 |
|
All Multiple Circuit Units Feature Indoor/Outdoor Enclosure.
Models and Specifications Subject to Change Without Notice |